Sensitive information in support logs are redacted

Details

Detail name Value
Changelog Number 32123
Type Bug
Status Resolved
Affected Versions Exasol 8.0.0
Fix Versions Exasol 2026.1.2, Exasol 2025.1.16
Resolution Date 2026-08-28

Description

When collecting logs with command exasupport or through ConfD job debug_collect sensitive information can be appended to the logs. The impact is limited, as only users with administration privileges can create and download such archives.

This change updates the collection process so sensitive files under /exa/etc have sensitive lines redacted on the generated log archive.

Workaround

There is no direct workaround. However this can be mitigated by redacting the log archive before sharing it with Exasol Support. These log archives never leave the cluster on their own, they are generated inside the cluster where only administrators may access or copy them elsewhere.

Fix

Configuration files under /exa/etc have their sensitive information redacted.