Cluster node could fail during slow disk I/O
Details
| Detail name | Value |
|---|---|
| Changelog number | 25242 |
| Type | Bug |
| Status | Resolved |
| Affected versions | Exasol 8.0.0 |
| Fix versions |
Description
To detect hanging disks, the cluster operating system on each node periodically writes and flushes its own log file to disk. If a flush did not complete within 90 seconds, the node was taken out of the cluster on purpose. On slow storage, for example cloud disks under heavy I/O load, flushing the log file could take longer than this even though the disk was still working, which caused a node failure and, depending on the setup, a database restart or outage.
Workaround
Restart the affected node and start the database manually if it does not restart automatically.
Fix
The log file is no longer flushed to disk as part of this check. Hanging disks are still detected using a small dedicated file, so a node is only taken out of the cluster when its disk actually stops responding.