A remote volume with two or more options can't be used

Details

Detail name Value
Changelog Number 22297
Type Bug
Status Resolved
Affected Versions Exasol 8.0.0
Fix Versions Exasol 8.33.0, Exasol 8.29.7, Exasol 2025.1.0
Resolution Date 2025-01-29

Description

When adding two or more options on a remote volume it becomes impossible to access it. This is caused by a parsing error on the options field.

Workaround

Manually edit /exa/etc/remote_volumes files and remove spaces from the comma-separated options column. Please contact Exasol Support to guide you through this process.

Fix

The automatically generated /exa/etc/remote_volumes files do not contain spaces in the options column.